KFM-2100 FLASH Meter
For Both Flash and Ambient Light Readings
Simple, Easy-to-Use, Accurate.
Specifications
Names of parts
1 Receptor head
Swivels 270° and accepts the Flat Diffuser
2 Power button
3 Viewfinder
4 Spot (reflected-light) measurement button
5 Incident-light measurement button
6 Data panel
Easy-to-read to give you the information you need at a glance.
7 Up/down dial
Used to set various values, such as ISO, shutter speed, calculation mode, etc.
8 ISO button
For setting the main ISO using the up/down dial.
9 LATITUDE button
Sets the Latitude display and monitor functions to standby.
10 MODE button
Changes the measuring mode.
11 Instant-film ISO button
For setting a secondary ISO (such as that of instant film for test shots) and displaying the exposure based on this ISO.
12 Clear button
Clears all measurement data from memory and cancels the standby status of the
latitude display and brightness difference functions.
13 S/A/H (shadow / average / highlight) button
Sets the Flash Meter VI's calculation function; desired function is selected using the up/down dial. (Shadow / highlight available only for reflected-light measurements.)
14 MEMORY button
Stores the present measurement in memory. Up to 10 measurements can be stored.
15 Sync terminal
16 Battery chamber cover
Specifications
Type: Hand-held digital Exposure meter for ambient and flash light
Reception Method: Incident-light readings and spot reflected light readings
Receptors: Incident- Spherical diffuser, 270° Rotating receptor head
Spot- Spot optical system built-in to viewfinder with 1° measurement angel
Capable of displaying data on ambient and spot measurements simultaneously
Receptor Elements: Silicon photocell
Measuring Modes: AMBI- Ambient light,
CORD- Flash w/sync cord
NON-CORD- Flash without sync cord
Measuring Range: Ambient light:
Incident : EV -2.0 to 19.9
Spot: EV 2.0 to 24.5
Flash:
Incident: F No. 1.0 to 128 +0.9 stop
Spot: F No. 2.8 to 128 +0.9 stop
+/- 0.1 stop
Measuring Distance: 4.2 ft (1.3m) to infinity
Optical System: Single-lens reflect type with fixed focal point
Field of view: 12 x 17° with 1° area marked by a circle
Magnification: 1.2x
Eyepiece adjustment: --3.0 to +1.0 diopters
Repeatability: +/- 0.1 EV
Calibration constant: -
Incident: -C=330 (spherical diffuser), C-250 (flat Diffuser)
Spot: K = 14
Display Range: -
F Number: F No. 1.0 to 128 + 0.9 stops (0.1 stop incr.)
EV value: -17 to 40.9 (0.1 stop incr.)
Shutter speed: -10 to +10 (0.1 stop)
Ambient: 30 minutes to 1/16000 sec. (1, 1/2, or 1/3 stop increments
Flash: 30 minutes to 1/1000 sec. (1, 1/2, or 1/3 stop increments
Frame Rate: 8, 12, 16, 18, 24, 25, 30, 32, 64, 128 frames/sec
ISO sensitivity: 3 to 8000 (1/3 stop)
Exposure Difference: -10 to +10 (0.1 stop)
Analog Scale: Ratio between Flash and Ambient 0 to 100% in 25% increments
Other Functions: Latitude display function
Analyze function
Exposure Calculation function (S/A/H)
Memory function (up to 10 measurements)
Monitor function,
Indication correction function
Power: one AA Alkaline dry-cell battery
Battery Life: Approx. 30 hours continuous reading in AMBI mode.
Operation Temperature range: 15 to 120° (-10 to + 50 C) with 85% relative humidity
Dimensions: 2.6 in (66mm) W x 6.9 in (175mm) H x 1.2 in. (31mm) D
Weight: 6.0 oz. (170g) w/o battery
Standard Accessories: Spherical diffuser, neck strap, case
Copyright © Kenko Tokina Co., Ltd. All rights reserved. Terms of Use | Privacy Policy